Metadata-Version: 2.1
Name: sml2mqtt
Version: 0.1
Summary: A sml (Smart Message Language) to MQTT bridge
Home-page: https://github.com/spacemanspiff2007/sml2mqtt
Author: spaceman_spiff
License: UNKNOWN
Project-URL: GitHub, https://github.com/spacemanspiff2007/sml2mqtt
Description: # sml2mqtt
        [![Tests Status](https://github.com/spacemanspiff2007/sml2mqtt/workflows/Tests/badge.svg)](https://github.com/spacemanspiff2007/sml2mqtt/actions?query=workflow%3ATests)
        [![PyPI - Python Version](https://img.shields.io/pypi/pyversions/sml2mqtt)](https://pypi.org/project/sml2mqtt/)
        [![Updates](https://pyup.io/repos/github/spacemanspiff2007/sml2mqtt/shield.svg)](https://pyup.io/repos/github/spacemanspiff2007/sml2mqtt/)
        [![PyPI](https://img.shields.io/pypi/v/sml2mqtt)](https://pypi.org/project/sml2mqtt/)
        [![Downloads](https://pepy.tech/badge/sml2mqtt/month)](https://pepy.tech/project/sml2mqtt/month)
        
        _A simple sml to mqtt bridge_
        
        
        sml2mqtt is a asyncio application that can read multiple sml (Smart Message Language) streams 
        from energy meters and report the values through mqtt.
        
        ## Installation
        
        Navigate to the folder where the virtual environment shall be created (e.g.).
        ```
        cd /opt/sml2mqtt
        ```
        If the folder does not exist yet you can create it with the ``mkdir`` command.
        
        
        Create virtual environment (this will create a new subfolder "venv")::
        ```
        python3 -m venv venv
        ```
        
        Go into folder of virtual environment
        ```
        cd venv
        ```
        
        Activate the virtual environment
        ```
        source bin/activate
        ```
        
        Install sml2mqtt
        ```
        python3 -m pip install --upgrade pip sml2mqtt
        ```
        
        
        Run sml2mqtt
        ```
        sml2mqtt --config PATH_TO_CONFIGURATION_FOLDER
        ```
        A good configuration path would be ```/opt/sml2mqtt```.
        sml2mqtt will automatically create a default configuration and a logfile there.
        
        ## Autostart
        
        To automatically start the sml2mqtt from the virtual environment after a reboot call::
        ```
        nano /etc/systemd/system/sml2mqtt.service
        ```
        
        and copy paste the following contents. If the user/group which is running sml2mqtt is not "openhab" replace accordingly.
        If your installation is not done in "/opt/sml2mqtt/venv/bin" replace accordingly as well::
        
        ```text
        [Unit]
        Description=sml2mqtt
        Documentation=https://github.com/spacemanspiff2007/sml2mqtt
        After=network-online.target
        
        [Service]
        Type=simple
        User=openhab
        Group=openhab
        ExecStart=/opt/sml2mqtt/venv/bin/sml2mqtt -c PATH_TO_CONFIGURATION_FILE
        
        [Install]
        WantedBy=multi-user.target
        ```
        
        Now execute the following commands to enable autostart::
        ```
        sudo systemctl --system daemon-reload
        sudo systemctl enable sml2mqtt.service
        ```
        
        It is now possible to start, stop, restart and check the status of sml2mqtt with::
        ```
        sudo systemctl start sml2mqtt.service
        sudo systemctl stop sml2mqtt.service
        sudo systemctl restart sml2mqtt.service
        sudo systemctl status sml2mqtt.service
        ```
        
        ## Analyze
        
        Starting sml2mqtt with the ``-a`` or ``--analyze`` arg will analyze a single sml frame and report the output.
        It's convenient way to check what values will be reported.
        
        ```
        sml2mqtt --config PATH_TO_CONFIGURATION_FOLDER -a
        ```
        Output
        ```
        SmlMessage
            transaction_id: 17c77d6b
            group_no      : 0
            abort_on_error: 0
            message_body <SmlOpenResponse>
                codepage   : None
                client_id  : None
                req_file_id: 07ed29cd
                server_id  : 11111111111111111111
                ref_time   : None
                sml_version: None
            crc16         : 25375
        SmlMessage
            transaction_id: 17c77d6c
            group_no      : 0
            abort_on_error: 0
            message_body <SmlGetListResponse>
                client_id       : None
                sever_id        : 11111111111111111111
                list_name       : 0100620affff
                act_sensor_time : 226361515
                val_list: list
                    <SmlListEntry>
                        obis           : 8181c78203ff
                        status         : None
                        val_time       : None
                        unit           : None
                        scaler         : None
                        value          : ISK
                        value_signature: None
                        -> (Hersteller-Identifikation)
                    <SmlListEntry>
                        obis           : 0100000009ff
                        status         : None
                        val_time       : None
                        unit           : None
                        scaler         : None
                        value          : 11111111111111111111
                        value_signature: None
                        -> (Geräteeinzelidentifikation)
                    <SmlListEntry>
                        obis           : 0100010800ff
                        status         : 386
                        val_time       : None
                        unit           : 30
                        scaler         : -1
                        value          : 123456789
                        value_signature: None
                        -> 12345678.9Wh (Zählerstand Total)
                    <SmlListEntry>
                        obis           : 0100010801ff
                        status         : None
                        val_time       : None
                        unit           : 30
                        scaler         : -1
                        value          : 123456789
                        value_signature: None
                        -> 12345678.9Wh (Zählerstand Tarif 1)
                    <SmlListEntry>
                        obis           : 0100010802ff
                        status         : None
                        val_time       : None
                        unit           : 30
                        scaler         : -1
                        value          : 0
                        value_signature: None
                        -> 0.0Wh (Zählerstand Tarif 2)
                    <SmlListEntry>
                        obis           : 0100100700ff
                        status         : None
                        val_time       : None
                        unit           : 27
                        scaler         : 0
                        value          : 555
                        value_signature: None
                        -> 555W (aktuelle Wirkleistung)
                    <SmlListEntry>
                        obis           : 8181c78205ff
                        status         : None
                        val_time       : None
                        unit           : None
                        scaler         : None
                        value          : XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
                        value_signature: None
                        -> (Öffentlicher Schlüssel)
                list_signature  : None
                act_gateway_time: None
            crc16         : 22117
        SmlMessage
            transaction_id: 17c77d6d
            group_no      : 0
            abort_on_error: 0
            message_body <SmlCloseResponse>
                global_signature: None
            crc16         : 56696
        ```
        
        ## Configuration
        
        Configuration is done in the ``config.yml`` file.
        
        ```yml
        logging:
          level: INFO
          file: /opt/sml2mqtt/sml2mqtt.log
        
        mqtt:
          connection:
            client_id: sml2mqtt
            host: localhost
            port: 1883
            user: ''
            password: ''
            tls: false
            tls_insecure: false
          publish:
            qos: 0        # Default QoS when publishing values
            retain: false # Default retain flag when publishing values
          topics:
            base topic: sml2mqtt  # Topic that will prefix all topics
            last will: status     # Last will topic
        
            # These aliases are replaced in the mqtt topics
            alias:
              0100010800ff: total_energy
        
        # Configuration of the sml devices
        devices:
        - device: COM24
          timeout: 3        # Timeout in seconds between messages from the device
          skip:
          - value ids that will
          - not be reported
        
        general:
          max wait: 120  # Time in seconds sml2mqtt waits for a value change until the value gets republished
        ```
Keywords: mqtt,sml,Smart Message Language,energy meter
Platform: UNKNOWN
Classifier: Development Status :: 4 - Beta
Classifier: Framework :: AsyncIO
Classifier: License :: OSI Approved :: GNU General Public License v3 or later (GPLv3+)
Classifier: Operating System :: OS Independent
Classifier: Programming Language :: Python :: 3.8
Classifier: Programming Language :: Python :: 3.9
Classifier: Programming Language :: Python :: 3 :: Only
Classifier: Topic :: Home Automation
Description-Content-Type: text/markdown