Description: # sdm_modbus
        
        sdm_modbus is a python library that collects data from Eastron SDM single- and three-phase kWh meters over Modbus RTU or Modbus TCP.
        
        Supported devices:
        * [Eastron SDM120M](https://www.eastroneurope.com/products/view/sdm120modbus)
        * [Eastron SDM230M](https://www.eastroneurope.com/products/view/sdm230modbus)
        * [Eastron SDM630M](https://www.eastroneurope.com/products/view/sdm630modbus)
        
        ## Installation
        
        To install, either clone this project and install using `setuptools`:
        
        ```python3 setup.py install```
        
        or install the package from PyPi:
        
        ```pip3 install sdm_modbus```
        
        ## Usage
        
        The script `example.py` provides a minimal example of connecting to and displaying all input and holding registers on a **SDM120** over **Modbus TCP**. To display values as a JSON object, add `--json`.
        
        ```
        usage: example.py [-h] [--unit UNIT] [--json] host port
        
        positional arguments:
          host         Modbus TCP address
          port         Modbus TCP port
        
        optional arguments:
          -h, --help   show this help message and exit
          --unit UNIT  Modbus device address
          --json       Output as JSON
        ```
        
        Output:
        
        ```
        SDM120(10.0.0.123:502, connectionType.TCP: timeout=1, retries=3, unit=0x1):
        
        Input Registers:
            Voltage: 237.00V
            Current: 8.63A
            Power (Active): -1919.70W
            Power (Apparent): 2035.57VA
            Power (Reactive): -676.70VA
            Power Factor: -0.94
            Phase Angle: 0.00°
            Frequency: 50.00Hz
            Imported Energy (Active): 1551.37kWh
            Imported Energy (Active): 1335.69kWh
            Imported Energy (Reactive): 0.01kVAh
            Exported Energy (Reactive): 4362.14kVAh
            Total Demand Power (Active): 1668.02W
            Maximum Total Demand Power (Active): 3347.26W
            Import Demand Power (Active): 0.00W
            Maximum Import Demand Power (Active): 3347.26W
            Export Demand Power (Active): 1668.02W
            Maximum Export Demand Power (Active): 2109.45W
            Total Demand Current: 7.57A
            Maximum Total Demand Current: 14.97A
            Total Energy (Active): 2887.07kWh
            Total Energy (Reactive): 0.00kVAh
        
        Holding Registers:
            Demand Time: 1s
            Demand Period: 60s
            Relay Pulse Width: 60ms
            Network Parity Stop: N-1
            Meter ID: 1
            Baud Rate: 9600
            P1 Output Mode: Export Energy (Active)
            Display Scroll Timing: 0s
            P1 Divisor: 0.001kWh/imp
            Measurement Mode: 0
            Pulse/LED Indicator Mode: Import + Export Energy (Active)
        ```
        
        ### Connecting
        
        If you wish to use Modbus TCP the following parameters are relevant:
        
        `host = IP or DNS name of your Modbus TCP gateway, required`  
        `port = TCP port of the Modbus TCP gateway, required`  
        `unit = Modbus device address, default=1, optional`
        
        While if you are using a Modbus RTU connection you can specify:
        
        `device = path to serial device, e.g. /dev/ttyUSB0, required`  
        `baud = baud rate of your SDM unit, defaults to factory default, optional`  
        `unit = Modbus device address, defaults to 1, optional`
        
        Connecting to the meter:
        
        ```
            >>> import sdm_modbus
        
            # SDM120 over Modbus TCP
            >>> device = sdm_modbus.SDM120(host="10.0.0.123", port=502)
        
            # SDM630 over Modbus RTU
            >>> device = sdm_modbus.SDM630(device="/dev/ttyUSB0", baud=9600)
        ```
        
        Test the connection:
        
        ```
            >>> device.connected()
            True
        ```
        
        Printing the class yields basic device parameters:
        
        ```
            >>> device
            SDM120(10.0.0.123:502, connectionType.TCP: timeout=1, retries=3, unit=0x1):
        ```
        
        ### Connecting to Multiple Devices
        
        Re-using an existing RTU or TCP connection is possible by providing an already connected device as `parent` when creating a new instance. This may be necessary if the Modbus TCP gateway only accepts a limited number of connections, or you wish to address multiple RTU devices on the same bus. For example:
        
        ```
            # Connect to a SDM630 over Modbus TCP
            >>> device_1 = sdm_modbus.SDM630(host="10.0.0.123", port=502, unit=1)
        
            # Connect to a SDM630 using the existing connection
            >>> device_2 = sdm_modbus.SDM630(parent=device_1, unit=2)
        ```
        
        ### Reading Registers
        
        Reading a single input register by name:
        
        ```
            >>> device.read("voltage")
            236.89999389648438
        ```
        
        Read all input registers by passing the `sdm_modbus.registerType.INPUT` enum to `read_all()`. Leave this blank to read both `INPUT` and `HOLDING` registers:
        
        ```
            >>> device.read_all(sdm_modbus.registerType.INPUT)
            {
                "voltage": 238.60000610351562,
                "current": 7.59499979019165,
                "power_active": -1673.800048828125,
                "power_apparent": 1797.5904541015625,
                "power_reactive": -655.4000244140625,
                "power_factor": -0.9311425685882568,
                "phase_angle": 0.0,
                "frequency": 50.0,
                "import_energy_active": 1556.35595703125,
                "export_energy_active": 1345.9210205078125,
                "import_energy_reactive": 0.014999999664723873,
                "export_energy_reactive": 4376.02001953125,
                "total_demand_power_active": 1659.360107421875,
                "maximum_total_demand_power_active": 3347.26318359375,
                "import_demand_power_active": 0.0,
                "maximum_import_demand_power_active": 3347.26318359375,
                "export_demand_power_active": 1659.360107421875,
                "maximum_export_demand_power_active": 2109.4541015625,
                "total_demand_current": 7.531858921051025,
                "maximum_total_demand_current": 14.968546867370605,
                "total_energy_active": 2902.277099609375,
                "total_energy_reactive": 4376.03515625
            }
        
            >>> device.read_all(sdm_modbus.registerType.HOLDING)
            {
                "demand_time": 1,
                "demand_period": 60,
                "relay_pulse_width": 60,
                "network_parity_stop": 0,
                "meter_id": 1,
                "baud": 2,
                "p1_output_mode": 4,
                "display_scroll_timing": 0,
                "p1_divisor": 0,
                "measurement_mode": 0,
                "indicator_mode": 0
            }
        ```
        
        ### Writing Registers
        
        Writing to holding registers is also possible. Setting a new baud rate, for example:
        
        ```
            >>> device.write("baud", 2)
            WriteMultipleRegisterResponse (28,2)
        ```
        
        You will need to **enable setup mode on your device** by pressing the setup button for 5 seconds, otherwise you will receive a `Exception Response(134, 6, GatewayNoResponse)` or similar.
        
        ### Register Details
        
        If you need more information about a particular register, to look up the units or enumerations, for example:
        
        ```
            >>> device.registers["voltage"]
                # address, length, type, datatype, valuetype, name, unit, batching
                (
                    0,
                    2,
                    <registerType.INPUT: 1>,
                    <registerDataType.FLOAT32: 11>,
                    <class 'float'>,
                    'Voltage',
                    'V',
                    1
                )
        
            >>> device.registers["p1_divisor"]
                # address, length, type, datatype, valuetype, name, unit, batching
                (
                    63760,
                    2,
                    <registerType.HOLDING: 2>,
                    <registerDataType.FLOAT32: 11>,
                    <class 'int'>,
                    'P1 Divisor',
                    ['0.001kWh/imp', '0.01kWh/imp', '0.1kWh/imp', '1kWh/imp'],
                    2
                )
        ```
        
        ## Contributing
        
        Contributions are more than welcome, especially testing on supported units, and adding other Eastron SDM units.
Platform: UNKNOWN
Classifier: Development Status :: 4 - Beta
Classifier: Programming Language :: Python :: 3.7
Classifier: Operating System :: OS Independent
Classifier: Environment :: Console
Classifier: Natural Language :: English
Classifier: Intended Audience :: Developers
Classifier: License :: OSI Approved :: MIT License
Requires-Python: >=3.7
Description-Content-Type: text/markdown