TINKERplate Command Reference

Definitions:
addr - TINKERplates have jumpers on the board that allow their address to be set
to a value between 0 and 7. Almost all commands will require an addr argument.

chan - most commands will require that a channel be specified. The analog
terminal block has channels 1 through 4 while the Digital I/O port has channels
numbered 1 through 8.

>>>SYSTEM FUNCTIONS<<<
help() - prints this reference to the screen - typically used from the command
line.
setMODE(addr,chan,mode) - this function is used with the Digital I/O block to
control its operating mode. When used in a script, it only has to be issued
once. The mode argument is a string that can be upper or lower case.
The following arguments are supported:
‘DIN’ - Data In - defaults at powerup.
‘DOUT’ - Data Out
‘BUTTON’ - Button
‘PWM’ - Pulse Width Modulator
‘RANGE’ - Ultrasonic Range Measurement
‘TEMP’ - Temperature
‘SERVO’ - Servo Motor
‘RGBLED’ - Neopixel® Driver

setDEFAULTS(addr) - returns all Digital I/O ports to simple inputs
getFWrev(addr) - returns the revision of the TINKERplate firmware
getHWrev(addr) -  returns the revision of the TINKERplate hardware
getVersion() -  returns the revision of the TINKERplate Python 3 module
getID(addr) - returns the string “Pi-Plate TINKERplate”
RESET(addr) - resets the TINKERplate to the power on state 

>>>ANALOG FUNCTIONS<<<
getADC(addr, chan) – returns a 12-bit measurement of the voltage appearing on
the designated chan argument. Returned values will be in the range of 0.0 to
12.0 volts.

getADCall(addr) – returns a list of measurements from all four channels on the
TINKERplate located at addr. Using this function is slightly faster than reading
the channels one at a time.

getPOT(addr,chan,*range) – this function will return a number from 0.0 to 100.0
that represents the percentage value of the wiper location on the potentiometer.
When this command is used without the optional range argument, the TINKERplate
assumes that the potentiometer is connected to a +5V voltage source. If you
choose to connect your potentiometer to any other voltage source, then range
should be set to the value of that source.

>>>RELAY FUNCTIONS<<<
Note that most RELAY commands require the following two arguments:
addr – the address of the TINKERplate. Valid values are 0 through 7
relay – the desired relay on the TINKERplate. Valid values are 1 and 2.

relayON(addr,relay) – energizes the designated relay: closes the NOx contact and
opens the NCx contact

relayOFF(addr,relay) – de-energizes the designated relay: opens the NOx contact
and closes the NCx contact

relayTOGGLE(addr,relay) – toggles the state of the designated relay. If the
relay referenced in the relay argument is de-energized before this command is
issued, it will be energized afterwards. If the relay is energized before this
command is issued, it will be de-energized afterwards.

relayALL(addr,relays) – uses a single argument to control the state of both
relays. See the table below for an explanation of each value. Valid arguments
for relay are 0 through 3.

Value NO1     NC1     NO2     NC2
  0   open    closed  open    closed
  1   closed  open    open    closed
  2   open    closed  closed  open
  3   closed  open    closed  open

relaySTATE(addr,relay) – returns the status of the relay designated in the relay
argument. Returns a 0 if the designated relay is not energized: NCx is closed
and NOx is open. Returns a 1 if the designated relay is energized: NCx is open
and NOx is closed.

>>>LED FUNCTIONS<<<
setLED(addr,chan,*brightness) – this command will simply turn an LED off and 
on when used with chan values of 0 through 8. The optional brightness 
argument can be used to set the brightness of the attached LED to a range 
from 0 to 100%. The brightness argument can only be used with channels 1 
through 6.

clrLED(addr,chan)– turns off the LED connected to the channel called out in 
the chan argument.

toggleLED(addr,chan)– toggles the state of the LED connected to the channel 
called out in the chan argument. If the LED was OFF before this command was 
issued then it will be turned ON afterwards. Conversely, if the LED was ON 
before this command was issued then it will be turned OFF afterwards.

>>>RGB LED FUNCTIONS<<<
setMODE(addr,chan,’rgbled’) – this is the mode command for configuring a 
channel as an RGB LED output driver. It only needs to be issued once. Valid 
chan values are 1, 2, 3, 4, 5, 6, 7, and 8.

setRGB(addr,chan,red,grn,blu) – this command will set the first LED 
connected to the specified channel to the RGB color combination called out 
by the three red, grn, and blue arguments. The values of these arguments 
can range from 0,0,0 to 255,255,255. Some basic colors include:

red: 255,0,0
green: 0,255,0
blue: 0,0,255
yellow: 255,255,0
orange: 255,165,0
magenta: 255,0,255
cyan: 0,255,255
white: 255,255,255
off: 0,0,0

setRGBSTRING(addr,chan,string) - this command will control a string of up to 
64 RGB LEDs. The string argument is a list of sequential rgb values and 
has valid lengths of 3 to 192 (3*64) values. The values should be arranged as 
r1,g1,b1,r2,g2,b2...rn,gn,bn.

>>>SERVO FUNCTIONS<<<
setMODE(addr,chan,’servo’) – this is the mode command for configuring a 
channel as a servo controller. It only needs to be issued once. When 
issued, any attached servo will be initialized to an angle of 90 degrees.

setSERVO(addr,chan,angle) – this command instructs the servo connected to 
chan to move to the angular position passed in the angle argument. Note 
that the angle variable assumes units of degrees and can only accept values 
between 0.0 and 180.0

setSERVOlow(addr,value) – while developing the TINKERplate, we found that 
not all servos behave the same way when it comes to timing. If you don’t 
believe your servo motor is returning to the 0 degree position. you can 
adjust the low side value and “dial it in” until your are satisfied with 
its position. Set value to a decimal number towards the low end of 0.5 to 2.45. 
Note that the default servo settings are enabled for the SG90.

setSERVOhigh(addr,value) – you can dial in your 180 degree position with 
this command. Set value to a decimal number towards the high end of 0.5 to 
2.45 until you are satisfied with maximum rotation angle. Note that these 
values are not stored on the TINKERplate and will have to be set everytime 
you choose to use a servo that requires custom values.

>>>PWM FUNCTIONS<<<
setMODE(addr,chan,’pwm’) – this is the mode command for configuring a 
channel as a PWM output. It only needs to be issued once. Valid chan values 
are 1, 2, 3, 4, 5, and 6.

setPWM(addr,chan,dutyCycle) – Once a channel has been configured as a PWM 
output, use this command to control the duty cycle. The dutyCycle argument 
is in units of percent and has a valid range of 0.0 to 100.0. Valid chan 
values are 1, 2, 3, 4, 5, and 6.

>>>DIGITAL I/O<<<
INPUT FUNCTIONS
setMODE(addr,chan,’din’) – this is the mode command for configuring a 
channel as a digital input. It only needs to be issued once.

getDIN(addr,chan) – returns the input status of the channel configured as a 
digital input. Returned values are 0 for a low voltage (<1V) and 1 for a 
high voltage (>2.3V). Input voltages between 1 and 2.3V will return 
unpredictable results.

getDINall(addr) – returns the value of all the digital inputs regardless of 
their mode. The returned value is an 8-bit number with the following 
mapping:
 -------------------------------------------------------
|chan 8|chan 7|chan 6|chan 5|chan 4|chan 3|chan 2|chan 1|
 -------------------------------------------------------
OUTPUT FUNCTIONS
setMODE(addr,chan,’dout’) – this is the mode command for configuring a 
channel as a digital output. It only needs to be issued once.

setDOUT(addr,chan) – sets the spcified channel to a high voltage

clrDOUT(addr,chan) – sets the spcified channel to a low voltage

toggleDOUT(addr,chan) – inverts the current output. If the output was low 
before this command was issued then it will be set to a high value 
afterwards. Conversely, if the output was high before this command was 
issued then it will be set to a low value afterwards.

setDOUTall(addr,byte) – controls all of the DOUT-configured channels with a 
single command. The following 8-bit mapping again applies:
 -------------------------------------------------------
|chan 8|chan 7|chan 6|chan 5|chan 4|chan 3|chan 2|chan 1|
 -------------------------------------------------------
>>>TEMPERATURE<<<
setMODE(addr,chan,’temp’) – this is the mode command for configuring a 
channel as a temperature sensor. It only needs to be issued once. Valid 
chan values are 1, 2, 3, 4, 5, 6, 7, and 8.

getTEMP(addr,chan,*scale) – this function returns the last value measured on 
the DS18B20 connected to the port designated by the chan argument.  This 
command supports an optional scale argument that overrides the global 
settings. Valid arguments for scale are ‘f’ for Fahrenheit, ‘c’ for 
Celcius, and ‘k’ for Kelvin.

setSCALE(scale) – the TINKERplate sets the default temperature scale to 
Fahrenheit. However, this can be overriden with this command. Valid 
arguments for scale are ‘f’ for Fahrenheit, ‘c’ for Celcius, and ‘k’ for 
Kelvin.

getSCALE() –  this command returns a single character that denotes the 
current global temperature scale. Returned values will be ‘f’ for 
Fahrenheit, ‘c’ for Celcius, and ‘k’ for Kelvin.

>>>DISTANCE MEASUREMENT<<<
setMODE(addr,channelpair,’range’) – this is the mode command for configuring 
a channel pair for a range sensor. It only needs to be issued once. Valid 
channelpair values are 12, 34, 56, and 78.

getRANGE(addr,channelpair,*units) – this function returns the average of the 
last 8 range measurements. Because of this, the returned values will be be 
more consistent but will change slowly if the measurement distance changes. 
Again, a channel pair has to be specified. An optional units argument can 
be used to return values in units other than the current default. Note that 
this command will return with a “sensor failure” message if:
no pinger is attached to the input the mode for this channel pair has not been
set to ‘range’ the pinger is blocked

getRANGEfast(addr,channelpair,*units) – this function returns the most 
recent range measurement. Returned values will have more variation but it 
will show a much faster response to changes in distance. Again, a channel 
pair has to be specified. An optional units argument can be used to return 
values in units other than the current default.

setUNITS(units) – As mentioned above, the TINKERplate defaults to inches as 
a measurement of distance. Use this command to change the default. Valid 
values for units are ‘cm’ and ‘in’. Note that this command only has to be 
issued once.

getUNITS() – This command will return the current units of distance used by 
the TINKERplate. Returned values will be one two character strings: ‘in’ or 
‘cm’

>>>BUTTON<<<
setMODE(addr,chan,’button’) – this is the mode command for configuring a 
channel as a button. It only needs to be issued once.

getBUTTON(addr,chan) – this will return a debounced button input.
Returns a 0 (zero) if the attached button is not closed
Returns a 1 (one) if there is closure between the input and ground

>>>METER<<<
openMETER(*linesel) – before using a meter, call this function first. If no 
argument is included, a 1 line meter will be created. If more than 1 line 
of data is required, pass a number between 1 and 12 in the options linesel 
argument.

setMETER(value,unit,descriptor,*linesel) – update the data on the optional 
line of the meter with the specified value, unit, and descriptor.

setTITLE(title) – changes the default title of the METER window to the 
string contained in the title argument

setCOLOR(newcolor) – use this function to change the color of the meter text 
from the default of green. The newcolor argument is a tuple of the three 
colors: (red, blue, green). Each of these are 8-bit values their range is 0 
to 255. To display dark yellow for example you would pass a tuple of (128, 
128, 0) in the newcolor argument.

closeMETER() – closes the open on-screen meter