Metadata-Version: 2.4
Name: guntamatic
Version: 1.0.3
Summary: module to get data from a Guntamatic heater e.g. BMK 20
Home-page: https://github.com/JensTimmerman/guntamatic
Author: Jens Timmerman
Author-email: guntamatic@caret.be
License: Apache License 2.0
Classifier: Development Status :: 3 - Alpha
Classifier: License :: OSI Approved :: Apache Software License
Classifier: Programming Language :: Python
Classifier: Programming Language :: Python :: 3.7
Classifier: Programming Language :: Python :: 3.8
Classifier: Programming Language :: Python :: 3.9
Classifier: Programming Language :: Python :: 3.10
Classifier: Programming Language :: Python :: 3.11
Classifier: Topic :: Internet :: WWW/HTTP
Requires-Python: >=3.7
Description-Content-Type: text/markdown
Requires-Dist: requests
Dynamic: author
Dynamic: author-email
Dynamic: classifier
Dynamic: description
Dynamic: description-content-type
Dynamic: home-page
Dynamic: license
Dynamic: requires-dist
Dynamic: requires-python
Dynamic: summary

This python module allows you to contact your Guntamatic BMK heater and get operational status information
It includes an example binary 'heater.py' which can be installed as the guntamatic binary to instantly get data in your cli.
The Guntamatic class can be used by IOT frameworks to be called regularly and plot data and the like.

The exact outputs might depend on your model and firmware.


## release history
1.0.1: don't generate an empty sensor as last line, skip empty lines
1.0.2: update homepage
1.0.3: clean up repo

## tests
PYTHONPATH=. pytest tests/test_heater.py

## roadmap
Currently this library only uses daqdata.cgi and dacdesc.cgi
There is also a status.cgi json interface, and probably a lot more is possible when you have an api key (https://github.com/openhab/openhab-addons/tree/main/bundles/org.openhab.binding.guntamatic )
To be added in the future.

## Example Data

The following sensors are available for a Guntamatic BMK 20 heater:

| Sensor | Value | Unit |
|--------|-------|------|
| Running | Service Ign. | |
| Boiler temperature | 14.09 | °C |
| Outside Temp. | 16.15 | °C |
| Buffer load. | 22 | % |
| Buffer Top | 44.56 | °C |
| Buffer Mid | 43.48 | °C |
| Buffer Btm | 34.01 | °C |
| Boil.shunt pump | 0 | % |
| Suction fun | 0.00 | % |
| Primary air | 0.00 | % |
| Seconday air | 0.00 | % |
| CO2 Content | 18.05 | % |
| DHW 0 | 44.50 | °C |
| DHW Pump 0 | 0 | % |
| DHW 1 | -20.00 | °C |
| DHW Pump 1 | 0 | % |
| DHW 2 | -20.00 | °C |
| DHW Pump 2 | 0 | % |
| Heating circulation pump 0 | OFF | |
| Room Temp:HC 0 | 60.00 | °C |
| Room Temp:HC 1 | 24.68 | °C |
| Flow is 1 | 18.61 | °C |
| Heating circulation pump 1 | OFF | |
| Room Temp:HC 2 | 21.77 | °C |
| Flow is 2 | 17.72 | °C |
| Heating circulation pump 2 | OFF | |
| Heating circulation pump 3 | OFF | |
| Room Temp:HC 3 | -9.00 | °C |
| Room Temp:HC 4 | -9.00 | °C |
| Flow is 4 | -20.00 | °C |
| Heating circulation pump 4 | OFF | |
| Room Temp:HC 5 | -9.00 | °C |
| Flow is 5 | 44.00 | °C |
| Heating circulation pump 5 | OFF | |
| Heating circulation pump 6 | OFF | |
| Room Temp:HC 6 | -9.00 | °C |
| Room Temp:HC 7 | -9.00 | °C |
| Flow is 7 | -20.00 | °C |
| Heating circulation pump 7 | OFF | |
| Room Temp:HC 8 | -9.00 | °C |
| Flow is 8 | 44.00 | °C |
| Heating circulation pump 8 | OFF | |
| Program | HEAT | |
| Program HC0 | OFF | |
| Program HC1 | OFF | |
| Program HC2 | HEAT | |
| Program HC3 | OFF | |
| Program HC4 | OFF | |
| Program HC5 | OFF | |
| Program HC6 | OFF | |
| Program HC7 | OFF | |
| Program HC8 | OFF | |
| Interuption 1 | | |
| Interuption 2 | | |
| Serial | 959103 | |
| Version | 32a | |
| Operat. time | 1122 | h |
| Service Hrs | 1876 | d |
| extra-WW. 1 | -20.00 | °C |
| extra-WW. 2 | -20.00 | °C |
| B extra-WW. 0 | OFF | |
| B extra-WW. 1 | OFF | |
| B extra-WW. 2 | OFF | |
| Flow is 0 | 44.00 | °C |
| Flow is 3 | 44.00 | °C |
| Flow is 6 | 44.00 | °C |
| Buffer Top 0 | -20.00 | °C |
| Buffer Btm 0 | -20.00 | °C |
| Buffer Top 1 | -20.00 | °C |
| Buffer Btm 1 | -20.00 | °C |
| Buffer Top 2 | -20.00 | °C |
| Buffer Btm 2 | -20.00 | °C |
| Auxiliary pump 0 | OFF | |
| Auxiliary pump 1 | OFF | |
| Auxiliary pump 2 | OFF | |

> Note: Sensors with a value of `-20.00 °C` are typically not connected.